Quote:
Originally Posted by ProPs
you might want to find out if the ballast you have is a pulse or a probe style ballast.. tar ballast were design for probe start style bulbs but i've seen some where its a pulse start... ushio and most european bulbs [ie. radium] run on a pulse start style ballast..
heres a good link
http://www.aquarium-lighting-guide.c...al_halide_ansi
|
Props, a tar ballast can be a pulse, magnetic, or HQI so the above statment dosen't apply to this.
a USHIO is a europen bulbs which has been turned into a probe start so yes any of the above ballasts will fire it.
the only way you will have a problem is if you try using a pulse start bulb with a probe start ballast. the other way is fine.
Steve
__________________

*everything said above is just my opinion, and may or may not reflect the views of this BBS, its Operators, and its Members. If cornered on any “opinion” I post I will totally deny having ever said this in a Court of Law…Unless I am the right one*
Some strive to be perfect.... I just strive.