Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > Reef

Reply
 
Thread Tools Display Modes
  #11  
Old 11-28-2004, 02:05 AM
StirCrazy's Avatar
StirCrazy StirCrazy is offline
Member
 
Join Date: Oct 2001
Location: Kamloops, BC
Posts: 7,872
StirCrazy is on a distinguished road
Default

Quote:
Originally Posted by Tarolisol
Havent purchesed my 4-way yet, but as far as i know it will do one full rotaion in 1min. Actully ive heard people say they wish it would move faster. But im ok with the timing as it is. You think 3000gph is enough or tomuch. Also it only has to go up about 4 or 5 feet.
I have come to the point of thinking that a switching return is almost a waist of time when you look at the cost involved. I personaly am back to the point that instead of recreating a area where the waves crash and pound but rather a tidle surge area where you have a strong current that is predomantly in one direction with the odd eddy (like the ocean side of the reef) but you have to see if there is a max flow rate the switcher can handle and base it off of that. another important thing to find out is how big the internal passages are and how many will be open at once as this will determin the max flow rate you can put through it and going with a bigger pump would be a waist of money.

Steve
__________________
*everything said above is just my opinion, and may or may not reflect the views of this BBS, its Operators, and its Members. If cornered on any “opinion” I post I will totally deny having ever said this in a Court of Law…Unless I am the right one*

Some strive to be perfect.... I just strive.
Reply With Quote
  #12  
Old 11-28-2004, 12:42 PM
MitchM's Avatar
MitchM MitchM is offline
Member
 
Join Date: Mar 2002
Location: Water Valley, AB
Posts: 1,280
MitchM is on a distinguished road
Default

Quote:
Originally Posted by monza
My tank is going to be a just a little bigger, I'm going to run a ...

WP-MT4300SEQ22XSX-SW
Sequence 1000 pump 1/6 HP, max flow 3200 gph at 8.5 ft. that will be on a closed loop and a 4 way. I have a pump from my sump as well, a Aqua Medic 6500. I have another closed from my chiller that is a Aqua Medic 3500.

I'm going to have lots of flow I think. IMO I would run your 4 way on a closed loop and a small pump thru the sump.

Dave
Dave,
On a closed loop your head pressure is almost nil, so what's that pump supposed to put out at 0' head?

Mitch
Reply With Quote
  #13  
Old 11-28-2004, 05:08 PM
Tarolisol's Avatar
Tarolisol Tarolisol is offline
Member
 
Join Date: Sep 2004
Location: calgary
Posts: 1,020
Tarolisol is on a distinguished road
Default

They say the 4-way can handle over 8000gph. So With what you said what do you think is the best way to set up my tank. As how should i go about trying to achive the water movment for SPS.
Reply With Quote
  #14  
Old 11-28-2004, 05:19 PM
mr_alberta's Avatar
mr_alberta mr_alberta is offline
Member
 
Join Date: Apr 2003
Location: Edmonton, AB (University Area)
Posts: 2,506
mr_alberta is on a distinguished road
Default

You could always go for a smaller, pressure rated pump and use Eductors or Penductors instead.
Reply With Quote
  #15  
Old 11-28-2004, 06:10 PM
Tarolisol's Avatar
Tarolisol Tarolisol is offline
Member
 
Join Date: Sep 2004
Location: calgary
Posts: 1,020
Tarolisol is on a distinguished road
Default

Could you explain educators and pendators?
Reply With Quote
  #16  
Old 11-28-2004, 06:17 PM
monza monza is offline
Member
 
Join Date: Apr 2003
Location: Cowtown
Posts: 679
monza is on a distinguished road
Default

Mitch
4300gph- There will be 8 one inch outlets, two will always be on at one time. Trying to create a side to side sort of wave action in my fish whirl pool

Dave
Reply With Quote
  #17  
Old 11-28-2004, 07:28 PM
mr_alberta's Avatar
mr_alberta mr_alberta is offline
Member
 
Join Date: Apr 2003
Location: Edmonton, AB (University Area)
Posts: 2,506
mr_alberta is on a distinguished road
Default

A Penductor and Eductor work basically the same way. A Penductor is a little bit smaller though. It works a lot like a venturi actually. Basically what happens is the water coming out of the pump is restricted to a small opening thus increasing the velocity of the water. With the increased velocity, a low pressure area is created and the surrounding water is sucked in as well. It is supposedly able to increase the flow from an outlet by 5x or so. Therefore, even with a smaller pump (say only pumping out 800GPH per outlet), you could theoretically get it up to 4000GPH/outlet with the use of an eductor.

Unfortunately, this process created quite a bit of back pressure, so you'll most likely need a good pressure rated pump to use the optimally. The eductors themselves are quite bulky as well.

As for the Penductor, iirc, littlesilvermax on the forum here uses them on his tank with an OM 4-way, so I'd hit him up for some "real world" impressions of it.

Here is a link with much more info:

http://www.reefcentral.com/forums/sh...hreadid=372881
Reply With Quote
  #18  
Old 11-29-2004, 02:20 AM
Buccaneer's Avatar
Buccaneer Buccaneer is offline
Member
 
Join Date: Mar 2003
Location: DeWinton, Alberta
Posts: 1,075
Buccaneer is on a distinguished road
Default

Hey Dave & Sean ... I was using penductors on the closed loops on my old 300G ... if you want more info on them let me know.
__________________
Steve

“The most important decision you make is to be in a good mood.”
― Voltaire
Reply With Quote
  #19  
Old 11-29-2004, 02:27 AM
Tarolisol's Avatar
Tarolisol Tarolisol is offline
Member
 
Join Date: Sep 2004
Location: calgary
Posts: 1,020
Tarolisol is on a distinguished road
Default

So if those are penductors what do educators look like?
Reply With Quote
  #20  
Old 11-29-2004, 03:10 AM
mr_alberta's Avatar
mr_alberta mr_alberta is offline
Member
 
Join Date: Apr 2003
Location: Edmonton, AB (University Area)
Posts: 2,506
mr_alberta is on a distinguished road
Default

http://www.aquaticeco.com/index.cfm/.../9846/cid/2953
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 07:43 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.