			#11  
			
			
			
			
			
		 
		
		
	 | 
|||||
		
		
  | 
|||||
| 
	
	
		
			
			 I can't imagine J&L would have sold me a brand new malfunctioning unit 
		
	
		
		
		
		
			
				__________________ 
		
		
		
		
	
		
		
	
	
	Cheers Gary 604-319-0317  | 
| 
		 
			 
			#12  
			
			
			
			
			
		 
		
		
	 | 
|||||
		
		
  | 
|||||
| 
	
	
		
			
			 I'm going bloody insane. This should not be that difficult. I'm up at 4 am so gotta crash. When I get home, just for the sh#ts and giggles of it I'm going to take the old, functioning dry side on the right, and swap it with the new, malfunctioning side on the left. That is the ONLY thing I haven't tried. 
		
	
		
		
		
		
			
				__________________ 
		
		
		
		
	
		
		
	
	
	Cheers Gary 604-319-0317  | 
| 
		 
			 
			#13  
			
			
			
			
			
		 
		
		
	 | 
|||||
		
		
  | 
|||||
| 
	
	
		
			
			 When you're doing the reset are you doing it on the tank coupled with wet & dry sides together ? 
		
	
		
		
		
		
		
	
		
		
	
	
	 | 
| 
		 
			 
			#14  
			
			
			
			
			
		 
		
		
	 | 
|||||
		
		
  | 
|||||
| 
	
	
		
			
			 Both ways. Coupled together dry, aligned and in functioning position on tank...... 
		
	
		
		
		
		
			
				__________________ 
		
		
		
		
	
		
		
	
	
	Cheers Gary 604-319-0317  | 
| 
		 
			 
			#15  
			
			
			
			
			
		 
		
		
	 | 
|||||
		
		
  | 
|||||
| 
	
	
		
			
			 Try taking the unit off the tank , with the wet side off & far away  
		
	
		
		
		
		
		
		
			Plug it in then hold down mode button , it should start flashing white on the dial If it does hold down mode & set at the same time If it starts flashing white & yellow unplug the power cord from the drive box wait like 2 seconds and plug it back in Good luck Last edited by rusty shackleford; 12-23-2015 at 06:35 AM.  | 
| 
		 
			 
			#16  
			
			
			
			
			
		 
		
		
	 | 
||||
		
		
  | 
||||
| 
	
	
		
			
			 I had same error red/green arrive on the mp10 for my salt mixing station last night.  
		
	
		
		
		
		
		
	
		
		
	
	
	Found some corrosion on the power conecition pin driver side. Cleaned it up and good to go. HTH  | 
| 
		 
			 
			#17  
			
			
			
			
			
		 
		
		
	 | 
||||
		
		
  | 
||||
| 
	
	
		
			
			 Have you tried swapping the driver  
		
	
		
		
		
		
		
	
		
		
	
	
	If that is your problem PM me I have a spare.  | 
| 
		 
			 
			#18  
			
			
			
			
			
		 
		
		
	 | 
|||||
		
		
  | 
|||||
| 
	
	
		
			
			 Yup.....Swapped drivers. Faulted driver worked perfect on other pump. 
		
	
		
		
		
		
			
				__________________ 
		
		
		
		
	
		
		
	
	
	Cheers Gary 604-319-0317  |