  #11  
Old 01-16-2012, 10:18 PM
fishytime's Avatar
fishytime fishytime is offline
Member
 
Join Date: Mar 2007
Location: E-town
Posts: 5,390
fishytime will become famous soon enough
Default

Technically thats not true Robb......the primary should be able to handle the entire flow that the return puts into the tank, with the gate valve open all the way.....so if the emergency is the same diameter, then it should also be able to handle the flow if the primary drain is restricted more than the gate valve being closed to adjust the water line in the overflow......did that make sense?
__________________
260g mixed reef, 105g sump, water blaster 7000 return, Bubble King SM 300 skimmer, Aqua Controller Jr, 4 radions, 3 Tunze 6055s,1 tunze 6065, 2 Vortech MP40s, Vortech MP20, Tunze ATO, GHL SA2 doser, 2 TLF reactors (1 carbon, 1 rowa). http://www.canreef.com/vbulletin/showthread.php?t=50034 . Tank Video here http://www.vimeo.com/2304609 and here http://www.vimeo.com/16591694
Reply With Quote
  #12  
Old 01-16-2012, 10:26 PM
sphelps's Avatar
sphelps sphelps is offline
Member
 
Join Date: May 2006
Location: Lyalta, East of Calgary
Posts: 4,777
sphelps is on a distinguished road
Default

Quote:
Originally Posted by fishytime View Post
Technically thats not true Robb......the primary should be able to handle the entire flow that the return puts into the tank, with the gate valve open all the way.....so if the emergency is the same diameter, then it should also be able to handle the flow if the primary drain is restricted more than the gate valve being closed to adjust the water line in the overflow......did that make sense?
depends on the setup, an internal overflow for example could have two drains of equal size but the owner may decide to run the primary without a riser or a very short one which in a way is like a full siphon with the full height of the overflow adding to it's pressure. The back up will have a riser to the height of the overflow and won't be able to replicate the same pressure as the primary and fall short of matching the flow. However if the water can rise high enough over the emergency riser the effect will be very similar minus the friction and minor losses from created from the riser and it's entrance point but the amount you can allow the water to rise over the riser tube depends on how much clearance you have. The larger diameter to riser tube the closer you'll come to matching the capabilities of the primary.
Reply With Quote
  #13  
Old 01-18-2012, 12:31 AM
Parker's Avatar
Parker Parker is offline
Member
 
Join Date: Aug 2005
Location: Edmonton
Posts: 1,012
Parker is on a distinguished road
Default

On my set-up I don't run a riser on my primary and my emergency has a riser pretty close to 30" tall.
__________________
Robb
Reply With Quote
  #14  
Old 01-28-2012, 04:10 AM
CountryBoy72 CountryBoy72 is offline
Member
 
Join Date: Jan 2012
Location: Vancouver Island
Posts: 51
CountryBoy72 is on a distinguished road
Default

With the two pipes how far below the slots on the corner overflow does the main drain need to be ? An should the emergency drain be a 1/4", 1/2" , 3/4" , or 1" above the main drains height ? Can take pictures of my corner overflow if that helps too.
Reply With Quote
  #15  
Old 01-28-2012, 04:23 AM
CountryBoy72 CountryBoy72 is offline
Member
 
Join Date: Jan 2012
Location: Vancouver Island
Posts: 51
CountryBoy72 is on a distinguished road
Default



Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 05:20 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.