#1
|
|||||
|
|||||
![]() I am new to running gfo
My question is. Is there a way to tell if gfo is spent. My po4 was off the chart. To which I attribute my family feeding the tank twice a day. I was in aware of this so I fed in evening. I have remedied the feeding schedule and done wc. I know most People change gfo once a month or when they see a rise in po4 |
#2
|
||||
|
||||
![]() Test the outlet of your gfo reactor. If it's anything but 0ppm then change it.
|
#3
|
|||||
|
|||||
![]() Will do.
Wasn't sure if the outlet would be zero or if it was a gradual procedure |
#4
|
||||
|
||||
![]() Thats what i was thinking as well, Im not sure the water coming out of the reactor would be filtered to zero in a single pass. Ive heard every 6 months approx or when Phos starts to rise. I dont think there is any other way to tell as far as I know.
__________________
![]() - 33 Gal - 20Gal Sump, MP10/Hydor Powerheads, Aquaticlife 4x T-5HO, Vertex IN100, TLF w/Biopellets, Tunze ATO -45GAL Build in Progress!- |
#5
|
||||
|
||||
![]() Sorry my fingers were typing but my brain was asleep lol.
In most cases, no you will not have 0 phos on the outlet. So a better indication would be when the outlet is at the same phosphate level as the overall po4 level of the system. |
#6
|
||||
|
||||
![]() I change mine every 4-5 weeks
__________________
250G DD LED SPS R.I.P. 180G LED SPS 80"x36". 300G custom build Owner of Mountain Ridge Heating and Gas Class A gas fitter, HVAC |
#7
|
|||||
|
|||||
![]() If you have high phosphates gfo can be exhausted in a very short time (days) so if your battling problems it might be a good idea to test ( from the output of the reactor) frequently to stay on top of the problem.
|
#8
|
|||||
|
|||||
![]() +1 to the above, and I'll add the same ...
Test your output, compare it to your system, and change your media every 4-6 weeks if all is good. Keep a record of what's happening so you can keep an eye on when you initially need to change it and go from there. |
#9
|
|||||
|
|||||
![]() Thanks everyone.
I tested outlet and It is the same as tank. I'll change it today |