Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > Reef

Reply
 
Thread Tools Display Modes
  #1  
Old 12-03-2010, 01:20 AM
Madreefer's Avatar
Madreefer Madreefer is offline
Member
 
Join Date: Nov 2008
Location: Prince George
Posts: 2,064
Madreefer is on a distinguished road
Default Stupid Question Concerning Overflow Plumbing

In my overflow I have an adjustable telescopice pipe with an elbow at the top with an strainer. The height of it determines the water level in the tank. I don't know what it is called so that is the description. Question, how to take it out to clean it? If I remove the whole peice will all the water start draining in to the sump? How would I prevent this? I would like to take it out as there is some huge aptasia that are attached to it. I'm sure that is the breeding area for them. Any suggestions are greatly appreciated!
Reply With Quote
  #2  
Old 12-03-2010, 01:44 AM
e46er e46er is offline
Member
 
Join Date: Nov 2008
Location: Maple Ridge
Posts: 819
e46er is on a distinguished road
Default

That is called a durso style overflow just the water from the overflow will drain when the pipe is removed nothing you can do about it
__________________
250G DD LED SPS R.I.P.
180G LED SPS
80"x36". 300G custom build

Owner of Mountain Ridge Heating and Gas
Class A gas fitter, HVAC
Reply With Quote
  #3  
Old 12-03-2010, 01:45 AM
lorenz0's Avatar
lorenz0 lorenz0 is offline
Member
 
Join Date: May 2008
Location: calgary
Posts: 1,317
lorenz0 is on a distinguished road
Default

Turn off your return pump. Sounds like your not running a herbie and you only have the single drain.
Reply With Quote
  #4  
Old 12-03-2010, 01:48 AM
Madreefer's Avatar
Madreefer Madreefer is offline
Member
 
Join Date: Nov 2008
Location: Prince George
Posts: 2,064
Madreefer is on a distinguished road
Default

Quote:
Originally Posted by lorenz0 View Post
Turn off your return pump. Sounds like your not running a herbie and you only have the single drain.
I have 2 drains. I guess the only way to remove them with out draining the water would be to put a ball valve and closing them on each hose going to the sump. Correct?
Reply With Quote
  #5  
Old 12-03-2010, 02:25 AM
lorenz0's Avatar
lorenz0 lorenz0 is offline
Member
 
Join Date: May 2008
Location: calgary
Posts: 1,317
lorenz0 is on a distinguished road
Default

Like said before, if the return pump is turned off the only water that will drain will be what is in your overflow

but if you have ball valve on both, thats not an issue. just pullout your pipes for your emergency and your drain and clean them
Reply With Quote
  #6  
Old 12-03-2010, 03:04 AM
mark's Avatar
mark mark is offline
Member
 
Join Date: Nov 2002
Location: Edmonton AB
Posts: 4,212
mark is on a distinguished road
Default

if this standpipe is in a overflow chamber that's all the water the will flow into the sump. Easy enough to calculate the volume of the chamber and if your sump has remaining room.
__________________
my tank
Reply With Quote
  #7  
Old 12-03-2010, 03:43 AM
Madreefer's Avatar
Madreefer Madreefer is offline
Member
 
Join Date: Nov 2008
Location: Prince George
Posts: 2,064
Madreefer is on a distinguished road
Default

I should have mentioned that the overflow is full of water and there is some slots at the half way point to allow water to go inside. So the tank will drain to that point. Like I said "stupid question". So I think the only answer is the ball valves that I would have to put in before I remove the pipes.
Reply With Quote
  #8  
Old 12-03-2010, 04:13 AM
mark's Avatar
mark mark is offline
Member
 
Join Date: Nov 2002
Location: Edmonton AB
Posts: 4,212
mark is on a distinguished road
Default

seen some overflow chambers that are doubled layered, slits on bottom outside piece then water flows over the top of the inner layer.

Would seem rather silly that the slits on yours would be all the way through. Not a smart way to build overflow.
__________________
my tank
Reply With Quote
  #9  
Old 12-04-2010, 09:13 PM
Madreefer's Avatar
Madreefer Madreefer is offline
Member
 
Join Date: Nov 2008
Location: Prince George
Posts: 2,064
Madreefer is on a distinguished road
Default

Quote:
Originally Posted by mark View Post
seen some overflow chambers that are doubled layered, slits on bottom outside piece then water flows over the top of the inner layer.

Would seem rather silly that the slits on yours would be all the way through. Not a smart way to build overflow.
Thanks Mark yes it was double walled. I was able to take out both drains and both pipes from the return lines. I tried to vacum out as much of the sludge on the bottom but it was too thick for my "tank only shop vac". I poured a half a bucket of fresh water in the overflow and this is the water that came out that came out. This is after sitting in the bucket for 1hr.


After pouring water out this is the 2" of sludge that was left that was filled with some pretty big bristtle worms.


This tank has been setup for about 3 years. How often do you people clean out your overflows? I've never thought of it.
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 11:03 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.