Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > Product Review and Equipment Forum > Filtration and Skimmer Specific

Reply
 
Thread Tools Display Modes
  #11  
Old 01-03-2013, 02:21 PM
gregzz4's Avatar
gregzz4 gregzz4 is offline
On Hiatus
 
Join Date: Oct 2011
Location: Burnaby, B.C.
Posts: 4,890
gregzz4 will become famous soon enough
Default

Quote:
Originally Posted by Myka View Post
HM Digital DM2 as it has dual calibration where the DM1 has only one calibration screw for both probes which often do not read the same
Mindy, have you some more info on this ?
I'd like to know if I'm looking forward to some kind of failure
I currently own the DM-1 and the SM-1
Reply With Quote
  #12  
Old 01-03-2013, 02:27 PM
Myka's Avatar
Myka Myka is offline
Moderator
 
Join Date: Mar 2004
Location: Saskatoon, SK.
Posts: 11,268
Myka will become famous soon enough
Default

What info do you want? Google for owner's manual for the DM2 to compare. Have you tried calibrating yours yet? Put both probes into the same glass of tap water and see if they read the same. If they do you're lucky (for now), if they don't read the same then there is nothing you can do to get them to read the same. Then you need to set the lower reading one to the calibration solution (usually 342 ppm), and if the second one then reads 3 ppm higher you just have to remember that 3 ppm on the second one means "0". That's about all you can do.
__________________
~ Mindy

SPS fanatic.

Reply With Quote
  #13  
Old 01-03-2013, 02:30 PM
gregzz4's Avatar
gregzz4 gregzz4 is offline
On Hiatus
 
Join Date: Oct 2011
Location: Burnaby, B.C.
Posts: 4,890
gregzz4 will become famous soon enough
Default

I wasn't expecting to hear issues

I've never had to cal mine since I bought them
Looks like I'll have some fun to deal with in the near future ...

Oh, and thanks for the info

Last edited by gregzz4; 01-03-2013 at 02:33 PM.
Reply With Quote
  #14  
Old 01-03-2013, 02:38 PM
gregzz4's Avatar
gregzz4 gregzz4 is offline
On Hiatus
 
Join Date: Oct 2011
Location: Burnaby, B.C.
Posts: 4,890
gregzz4 will become famous soon enough
Default

Thanks again Mindy for the info
Every day there is something to learn about
Sucks that it's about my own gear
Reply With Quote
  #15  
Old 01-03-2013, 02:51 PM
Reef Pilot's Avatar
Reef Pilot Reef Pilot is offline
Member
 
Join Date: Nov 2010
Location: Langley BC
Posts: 1,883
Reef Pilot is on a distinguished road
Default

I have a dual TDS meter, one shows after RO and before DI, and the other shows after DI. When the RO tds starts to go up, it tells me it is time to flush the membrane. My final RO/DI water is normally 0 or 1. When it goes up it is time to change DI. When flow slows down, it is time to change the sediment and carbon filters.
__________________
Reef Pilot's Undersea Oasis: http://www.canreef.com/vbulletin/sho...d.php?t=102101
Frags FS: http://www.canreef.com/vbulletin/sho...d.php?t=115022
Solutions are easy. The real difficulty lies in discovering the problem.
Reply With Quote
  #16  
Old 01-03-2013, 02:57 PM
gregzz4's Avatar
gregzz4 gregzz4 is offline
On Hiatus
 
Join Date: Oct 2011
Location: Burnaby, B.C.
Posts: 4,890
gregzz4 will become famous soon enough
Default

Pretty much what I was trying to say about TDS meter locations

Do you have a pressure gauge ?
Reply With Quote
  #17  
Old 01-03-2013, 02:58 PM
Myka's Avatar
Myka Myka is offline
Moderator
 
Join Date: Mar 2004
Location: Saskatoon, SK.
Posts: 11,268
Myka will become famous soon enough
Default

Quote:
Originally Posted by gregzz4 View Post
I've never had to cal mine since I bought them
What do you mean you've never had to? How long have you had the meter? You should calibrate every 3-6 months.
__________________
~ Mindy

SPS fanatic.

Reply With Quote
  #18  
Old 01-03-2013, 03:03 PM
Reef Pilot's Avatar
Reef Pilot Reef Pilot is offline
Member
 
Join Date: Nov 2010
Location: Langley BC
Posts: 1,883
Reef Pilot is on a distinguished road
Default

Quote:
Originally Posted by gregzz4 View Post
Pretty much what I was trying to say

Do you have a pressure gauge ?
I have a pressure gauge on the input source side only, which is my house pressure, and it is normally around 70.
__________________
Reef Pilot's Undersea Oasis: http://www.canreef.com/vbulletin/sho...d.php?t=102101
Frags FS: http://www.canreef.com/vbulletin/sho...d.php?t=115022
Solutions are easy. The real difficulty lies in discovering the problem.
Reply With Quote
  #19  
Old 01-03-2013, 04:04 PM
gregzz4's Avatar
gregzz4 gregzz4 is offline
On Hiatus
 
Join Date: Oct 2011
Location: Burnaby, B.C.
Posts: 4,890
gregzz4 will become famous soon enough
Default

Quote:
Originally Posted by Myka View Post
What do you mean you've never had to? How long have you had the meter? You should calibrate every 3-6 months.
I calibrated them when I set the unit up in May, so I guess I'm due for another cal session
I thought they were good for a year
Reply With Quote
  #20  
Old 01-03-2013, 04:05 PM
gregzz4's Avatar
gregzz4 gregzz4 is offline
On Hiatus
 
Join Date: Oct 2011
Location: Burnaby, B.C.
Posts: 4,890
gregzz4 will become famous soon enough
Default

Quote:
Originally Posted by Reef Pilot View Post
I have a pressure gauge on the input source side only, which is my house pressure, and it is normally around 70.
My input pressure is around 60psi
My pre-RO pressure (post sediment and carbon filter) is the same, but when it dropped below 50 this last fall, I replaced my sediment filter and all was good again

Last edited by gregzz4; 01-03-2013 at 04:07 PM.
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 07:11 AM.


Powered by vBulletin® Version 3.7.3