Been thinking about this the last hour or so and I think what may be happening, is if the pump is getting periods of slightly higher voltage, (which likely happens depending on other loads on the circuit) it will increase flow very slightly. This of course is a problem because the drain isn't set up for the extra flow so water accumulates in the overflow. It has even gotten to the point where the DT level is rising. It then also gets exacerbated because the ATO keeps topping off before it actually should be.
|
If you have a DC pump then that's the problem.Some of them don't keep a constant voltage which result's in more or less flow(happens to me with jebao12000)What i did is i tuned the gate valve that is just flowing a tiny bit in the emergency drain and when start to push more water it goes down on the emergency,usually doesn't last for long and go back in level.