Quote:
Originally Posted by reefwars
Without a cookie bribe? Not likely lol
Correct me if I'm wrong but a bean isn't just an extra drain it's the ability to run more gph with the syphon  so the bonus on a small tank is nil but on larger tanks you run more water through without having to use huge piping sizes 
|
I think you are partly wrong. The Herbie and the BA are both siphon drains so with the same size pipe they can handle the same flow. The BA adds the emergency drain, but also uses the second drain as a trickle (which is how many people run their Herbie). The trickle set up means that you shouldn't have to adjust the siphon drain gate valve once you have it tuned. That trickle can take more or less as minor variations change the flow through the main line.