The best way to install a swing check is vertical, then the head of water above the valve will always drive the flapper closed when the return pump stops. I just went to new Speedwave pump and pulled my check valve apart to clean it and it was spotless inside. Anti syphon hole or a short lock line outlet at the water surface is also a great idea, redundancy is a good thing.