Quote:
Originally Posted by Trevor W
Hey thanks for posting those pics for me! Yea they are only 1/16" as you can see before those pics I drained roughly 15 Gallons out of the display in anticipation of having to somehow widen those slits. When you look at the one photo you can see a scum line from my dry rock of where the water was before I took out the 15 gallons. From that point it raises to almost touching the euro brace and im sure if left it would go over it had it had enough water. At the point of just about touching the euro brace it really starts flowing into the overflow box but by this time it never equalizes and just runs the return pump chamber dry while the display slowly floods.
|
Hi Trevor
Yes we had a run of tanks that had this problem

didn't realize at the time the surface tension of water would back up with those size cuts! we figure it would look cleaner but never work out that way
give Denny a call at the shop at 5873237360 and i will have a new panel made up and overnight it out to you
thanks Dave