Thread: Reef Temp
View Single Post
  #1  
Old 07-14-2012, 05:00 AM
RuGlu6 RuGlu6 is offline
Member
 
Join Date: Sep 2008
Location: Vancouver PoMo
Posts: 829
RuGlu6 is on a distinguished road
Default

Quote:
Originally Posted by RuGlu6 View Post
24.5C 25.5C (78) here
http://www.wbuf.noaa.gov/tempfc.htm
Heater is my controller and water tubing coil cooled with cold tap water is my chiller.
I run a 1/4 inch OD tube from my RO/DI inlet to the sump, and back to the P-trap, with straight valve slightly open to the fast drip.
There is a 15 feet tube coil in the sump acts as a heat exchanger/cooler.
Back to the RO/DI waste line and in to the drain. water cost for a few short Summer month in Vancouver where it rains 9 month out of 12 is nothing compare to the cost of the controller and chiller and electricity to run the chiller.
This small heat exchanger coil works amazingly well. My tank is 65 gal + ~10 of water in the sump. For larger tanks i would just increase the size of the heat exchanger coil.
Reply With Quote