Thread: Warning
View Single Post
  #41  
Old 05-13-2012, 03:28 AM
banditpowdercoat's Avatar
banditpowdercoat banditpowdercoat is offline
Member
 
Join Date: Oct 2007
Location: 100 mile hse BC
Posts: 2,568
banditpowdercoat is on a distinguished road
Default

A AFI would offer more protection, but I think one needs both?. A GFI will only trip if it senses current going to ground, not back on the neutral. One can have a short on a GFI, between the hot and the Neutral and it not trip. Conversly, a AFI only trips when it senses an arc. Be it to ground or neutral. Most cases a AFI would work. Not on halide lights, I'm not sure. But say a pump leaks some to the tank, a AFI won't pick that up, a GFI will. AFI's can also trip by just switching or unpluging components. Heaters can sometimes trip them as well.

Like everything in this hobby, nothing is foolproof
__________________
Dan Pesonen


Umm, a tank or 5
Reply With Quote