Originally Posted by airdrie5
I just tried the calibration fluids that came with the GHL and the Pinpoint and this is what my refractometer measured.
GHL 50mS @ 25 degrees: 1.018
Pinpoint 53.0mS @ 25 degrees: 1.028
Makes no sense to me. Perhaps the calibration fluids are contaminated or old?
Contamination seems unlikely as both of the bottles have never been left open and are under 30 days old from both manufacturers (store purchased).
|
Makes sense to me, like I said the GHL offset needs to be set. Throw out the hydrometer reading and things make more sense. The refractometer reads 1.025 while the pin point reads 1.026. I would sway towards the refractometer being more accurate than the pin point but the fact these are very close is a good sign. So you can assume the refractometer is accurate so set the GHL offset to match.