Originally Posted by RuGlu6 View Post
The only thing so far is that i am very cautious about is pump connection method via soft rubber sleeves instead of hard piping it. The unit is holding water nicely and now is used externally, but i am watching it like a hawk! Planning a bottom container just to be on the safe side.
I wouldn't be too worried about the external piping being connected to the main chamber via the soft rubber seals as they appear to be just square uniseals from the posted pictures. I ran an external skimmer for over 3 years that used uniseals to connect the external plumbing to the main skimmer chamber and the only time it leaked was when I had to remove the piping and piece it back together after being in constant use for several years. If you are scared about the quality of the soft rubber sleeves, just order up some replacement uniseals as there are several online distributors that carry them in various sizes.
__________________
Do or do not....there is no try.