View Single Post
  #27  
Old 05-22-2011, 04:35 PM
StirCrazy's Avatar
StirCrazy StirCrazy is offline
Member
 
Join Date: Oct 2001
Location: Kamloops, BC
Posts: 7,872
StirCrazy is on a distinguished road
Default

hmmm.. I was wondering why I saw a subscribed post I didn't remember reciently LOL

a M80 ballast (true magnetic M80) which is only made by Advance transformers (north american company) should be pulling around 400 watts with a 250 watt SE bulb a little less with a DE bulb, at 310 watts I would say they put a M80 starter and capacitor on a pulse start ballast and used that. will be a little lower output this way (well a fair bit actualy) I am not saying thats what they did but I have seen that done. the other thing I saw once was a european ballast converted to NA voltage (easy to do) this gives different out put as they are not a HQI ballast but are simular.

Steve
__________________
*everything said above is just my opinion, and may or may not reflect the views of this BBS, its Operators, and its Members. If cornered on any “opinion” I post I will totally deny having ever said this in a Court of Law…Unless I am the right one*

Some strive to be perfect.... I just strive.
Reply With Quote