Originally Posted by Wayne View Post
What kind of failures might occur with the contollers? Do they have backup safetys?
They can be as simple or as complicated as you want. I was able to pick up a Tunze ATO used for a steal a few years ago but I run it plugged into my Neptune controller for some extra protection. I also use a kalkwasser reactor and there is some risk of raising the pH too high so I came up with this:

Max Change 030 M Then ATO OFF
If pH > 08.60 Then ALM ON
If pH > 08.40 Then ATO OFF
If Switch1 OPEN Then ATO OFF
If Switch1 CLOSED Then ATO ON
If Timer KAL = ON Then ATO OFF