View Single Post
  #21  
Old 11-23-2003, 02:35 AM
StirCrazy's Avatar
StirCrazy StirCrazy is offline
Member
 
Join Date: Oct 2001
Location: Kamloops, BC
Posts: 7,872
StirCrazy is on a distinguished road
Default

Quote:
Originally Posted by mnoll406
Hey Guys,
I fill a 8 gal bucket in a couple of hours.
Mike
at or beklow the recomended rated pressure a 50GPD membrain will only put out 2 gal per houre at a max rate (unless you are over pressuring it) so you are taking 4 hours to fill your 8 gal bucket at best with a 50 gal membrain. Also by dropping the temp down to 5 degrees C you can drop your output up to 30%. A TFT type membrain that we comenly use in the hoby and home drinking water is designed to have a minimum of 40PSI (this is what it to permatate the membraine) there are low PSI membrains out there and different types but the most commen is a TFT as it is what kent and all of the retail ones are.

I just filled 10 gall on the floor of my garage in 1 hour wen't out and forgot I was filling a 5 gal bucket.

Steve
__________________
*everything said above is just my opinion, and may or may not reflect the views of this BBS, its Operators, and its Members. If cornered on any “opinion” I post I will totally deny having ever said this in a Court of Law…Unless I am the right one*

Some strive to be perfect.... I just strive.
Reply With Quote