View Single Post
  #25  
Old 12-18-2009, 12:45 AM
golf nut golf nut is offline
Member
 
Join Date: Feb 2004
Location: just north of Toronto
Posts: 454
golf nut is on a distinguished road
Default

Quote:
Originally Posted by sphelps View Post
In the drawing you've provided Is there three drains in one? I've done this style of overflow before but only combined two drains into one:.
It can be three drains or two drains and one return, as I said initially it is one of hundreds of options.



Quote:
Originally Posted by sphelps View Post
The tools required are minor and the only modification required is to the bushing which just needs the internal edge ground off so the 1.25" pipe can be slipped all the way through and glued in place.
If you call minor tools a lathe and a mill then I agree,considering I had not planned on using sched 40 and that the tubes are engineered for flow then you do need proper tools

Quote:
Originally Posted by sphelps View Post
Does your design differ from this one? As far as I remember this design was really only practical if a 2" bulkhead could be used. The 2" pipe combined with a 1.25" pipe match up almost perfectly if sch40 is used. This is because the area of the 1.25" pipe slightly smaller than the area of the 2" pipe minus the space taken up by the 1.25" pipe but the larger area has more friction resulting from more surface area. Therefore the primary cannot exceed the secondary in flow meaning your limitation is simply the 1.25" pipe and you can size your return to match that.
If you would read before you typed you would see that I said to use proper flows and pipes accordingly

Quote:
Originally Posted by sphelps View Post
The one problem with this design is it simply isn't practical and makes very little sense to pursue it too far. The only time I have used this design is when I drilled a tank on site which had thick glass and drilling another hole would be more work
Practical means to do something that makes sense not because it was too much work.

Quote:
Originally Posted by sphelps View Post
In all other cases you're better off drilling a second hole. For example if you're planning a custom build adding the extra hole is minor and if you're not planning a custom build and you only have one drain hole chances are you won't be able to get a 2" bulkhead in there anyway.
Where can I not fit a 2" bulkhead?

Quote:
Originally Posted by sphelps View Post
I've also done another style of a single hole herbie, it was simply a single stockman stand pipe plumbed in the usual way. the difference was that at the base of the standpipe it could rotate within a couple, a large hole was drilled in the coupling and through the pipe of the standpipe so the two holes could line up. This would add a kind of gate valve to the standpipe itself and the idea was you would be able to adjust the valve so most of the water entered the lower part of the standpipe at full siphon and only a small amount went through the top. Now this of course didn't add the security of a second drain but simply made for a quieter standpipe.
The drawing shows that the siphon feed was reduced, don't waste money on a ball or gate valve simply install the correct size of restriction to control the siphon.
A typical silent, drain system in a 200 gallon tank takes up about 120 square inches and a ton of real estate and costs around $1000 I can do the same thing including a return and all the plumbing for a 1/4 of the cost and use up only 20 square inches,not using the method above but a different way .... now that's what I call practical.
Reply With Quote