I just discovered that the flow rate varies considerably depending upon how long the tubing is on the intake side. The values I reported above were with the intake tubing at 22" and when I re-calibrated pump 1 with 13" of tubing on the intake it was 47mL/minute.  
 
I guess I'll just have to set up each pump in place with the tubing laid out the way it will be once everything is operating and then re-calibrate. I know the instructions say the "tube on the intake side should be short", but is there a length that is considered too long or potentially too stressful for the pump to draw the fluid up? 
		
	
		
		
		
		
			
				__________________ 
				SPS Dedicated 24x24x20 Trimless Tank | 20 g Sump | Bubbble King Mini 160 Protein Skimmer w/ Avast Swabbie | NP Biopellets in TLF Phosban Reactor | ATI Sunpower 6 x 24W T5HO Fixture | EcoTech Vortech MP20 | Modified Tunze Nanostream 6025 | Eheim 1260 Return Pump | GHL Profilux Standalone Doser dosing B-Ionic | Steel Frame Epoxy Coated Stand with Maple Panels embedded with Neodymium Magnets 
 