View Single Post
  #10  
Old 10-27-2016, 12:48 PM
Myka's Avatar
Myka Myka is offline
Moderator
 
Join Date: Mar 2004
Location: Saskatoon, SK.
Posts: 11,268
Myka will become famous soon enough
Default

Quote:
Originally Posted by Humpty View Post
the overflows are in each corner. I have the stockman setup. and yes the sump is just over half full. Those flow rates were for the dc9000?
I just double checked and it looks like I have 3/4" return lines. Does that change the flowrate?
Google "DCS9000 flow chart" and double check yourself.

So put a 2" long piece of 3/4" pipe coming out of the 3/4" bulkhead. Attach a 3/4" by 1" reducer bushing, slide the reducer bushing into a 1" elbow and run that down to your 1.5" tee.

Or you could use two pumps, one for each side, and throttle them back.


Quote:
Originally Posted by dustinc View Post
I have a DCS9000 plumbed into a single 1" return... it does come with an adapter for 3/4" but I wouldn't go with a single 3/4"... I only run mine at 60%
Humpty needs to run a single 9000 at 90-100% for his tank size.
__________________
~ Mindy

SPS fanatic.


Last edited by Myka; 10-27-2016 at 12:51 PM.
Reply With Quote