Quote:
Originally Posted by Humpty
the overflows are in each corner. I have the stockman setup. and yes the sump is just over half full. Those flow rates were for the dc9000?
I just double checked and it looks like I have 3/4" return lines. Does that change the flowrate?
|
Google "DCS9000 flow chart" and double check yourself.
So put a 2" long piece of 3/4" pipe coming out of the 3/4" bulkhead. Attach a 3/4" by 1" reducer bushing, slide the reducer bushing into a 1" elbow and run that down to your 1.5" tee.
Or you could use two pumps, one for each side, and throttle them back.
Quote:
Originally Posted by dustinc
I have a DCS9000 plumbed into a single 1" return... it does come with an adapter for 3/4" but I wouldn't go with a single 3/4"... I only run mine at 60%
|
Humpty needs to run a single 9000 at 90-100% for his tank size.