Quote:
	
	
		| 
					Originally Posted by Humpty  the overflows are in each corner.  I have the stockman setup. and yes the sump is just over half full.  Those flow rates were for the dc9000?I just double checked and it looks like I have 3/4" return lines.  Does that change the flowrate?
 | 
	
 Google "DCS9000 flow chart" and double check yourself.
So put a 2" long piece of 3/4" pipe coming out of the 3/4" bulkhead. Attach a 3/4" by 1" reducer bushing, slide the reducer bushing into a 1" elbow and run that down to your 1.5" tee.
Or you could use two pumps, one for each side, and throttle them back.
	Quote:
	
	
		| 
					Originally Posted by dustinc  I have a DCS9000 plumbed into a single 1" return... it does come with an adapter for 3/4" but I wouldn't go with a single 3/4"... I only run mine at 60% | 
	
 Humpty needs to run a single 9000 at 90-100% for his tank size.